Product Details:

Type Still Camera
Style Hidden Camera
Sensor CMOS
Certificates CE,ROHS,FCC
Special Features Vandal-proof
Technology Pinhole
Place of Origin Guangdong, China (Mainland)
Brand Name Jove
Model Number ZH04/ZR705

Payment & Shipping Terms:

Minimum Order Quantity: 10 Set/Sets
Price: FOB shenzhen USD 0~58
Packaging Details: 1.Internal packing:gift box:Dimension:18*8.2*19.5cM3 Weight:0.17kg 2.Outer packing:carton box:Dimension:43*37.5*41cM3 Weight:1.0kg 3.One set in one gift box, 20 sets in one carton box.
Delivery Time: 5 days
Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability: 50,000 Set/Sets per Year

Detailed Product Description


Smoke alarm specifications :

smoke camera:

1)smoke detect alarm,                                     

 2)2.4GHz wireless camera: 1/3 color CMOS image sensor,

horizontal resolution:420 TV Lines; 

view angle:170degree(diagonal);                    

Lens:1.8mm;                                            

Min illumination:<0.5Lux;

View distance:100m almost

User's Annual:
1.Indepedant smoke Alarm:
1)Features:
Power:9V  alkaline batteries or Carbon-zinc batteries
Working current:Quiescent current<10uA,working current:20-50mA
Smoke sensitivity:compliance with UL217
Working temperature:40-120 Degrees Fahrenheit(4-50 degree)
The interface temperature of gases:10%-90%
The level of buzzer sound volume:85DB at 10feet
Battery life:at least one year
2)Installation:
Choose a proper place for  installating
As the holes of the installing stand ,make two holes on the ceiling or against the wall.
Drill two holes in  the middle of the space of the holes
Put the two plastics waist nails,Mounting brackets to the back close to the wall
Put nails in and  screw till the mounting brackets is firmed.
The detector is a kind of sealing device,not allowed to be opened.Please put the batter into the back compartment.
With the back of the detector close to the outlet of installing,and rotate by colockwise and ensure that the two heads of the nails have been sliding into the waist holes.
Press the test button  lightly to see whether the detector work normaly or not.
3)Procedure of woking,test and maintenance 
The detector has been working after it's installed,in this situation,the Light-emitting diode flashes once a minute.When Combustion particles
are detected,the detector will issure sonorous sound of the alarm till air recovers to calm.
Test:
Press the button keeping at least 3 minutes,LED light starts to flash,several seconds delay(without delay at Ion type),one
sonorous sound will be produced,it means that the detector is working.At the same time of waring,the LED flashes very quickly,also you can blow smoke into the camber to test the detector.(Test once a week to ensure a reliable tester work)
Avoid installing at the places as below:
1.too close to the door mouth,windows,fans ect where may influence the warining sensitivity as the air flows faster. 
2.Don't install in the high humility places, such as bathroom,garret or the place where the temperature is 39 degree above or lower than 5 degree.
Simple maitainance:
Clear the detector once 6 months in order to keep it good working efficency. First,close the power,then,sweep the dust with the soft brush,last,resume the power.
The problems happen as below:
1.It doesn't sound when you press the test button.
2.The smoke detector work but doesn't sound.
3.The LED won't be never flash stably.
Try to improve it as below:
1.Examin the power 
2.Simple cleaning
3.Ask for checking thoroughly
 from  Electrician.
If the methods above can improve thouroughly,please don't maintain by yourself,if the detector is still within the maintenance period,please send it back to our company as well as  the invoice(the  date proof).
Remarks:abnormal teperature also leads to false alarms,just keep the air circulating,the alrams will stop very soon.
Dust also can reduce the sensitivity of alarm,please improve it as the methods above.


 

Receiver:

1)Dual Output Mode: USB for PC and AV for TV/Monitor 
2) Built-in microphone for audio monitoring
3)High speed MPEG 4 compression,support real time image output
4)4-channel operation allows multiple (1-4) camera systems (optional)
5)Long operation range: up to 100 m clear line of sight or 30 m throug walls/ceilings
6)Compact, Lightweight and Super Mini size
7)Swivel bracket included for wall /ceiling mounting
8)Supports Windows 98/2000/XP MSN Messenger
9)This receiver not only have auto-scan channel function but also have skip channel function.

User's annual:

1.insert the disc to your PC,and then install it according the the remarks on it.

2.connect the receiver to your computer with the USB wire.



 

smoke alarm camera Kits smoke alarm camera Kits

Send your message to this supplier
« Prev Product 1 2 3 4 5 6 7 ... Next Product »

Other Products from this Supplier

Company Info

Jove Video Communication Limited
[China (Mainland)]
[Verified Member]

City: Shenzhen
Province/State: Guangdong
Country/Region : China (Mainland)

Business Type:Manufacturer, Distributor/Wholesaler

View Contact Details

Email this page Bookmark this page Print this Page